{"id":743,"date":"2010-04-13T04:07:09","date_gmt":"2010-04-13T08:07:09","guid":{"rendered":"http:\/\/www.tridens.si\/?p=743"},"modified":"2021-12-01T15:36:43","modified_gmt":"2021-12-01T15:36:43","slug":"brm-%ed%8c%8c%ec%9d%b4%ed%94%84%eb%9d%bc%ec%9d%b8-%ec%8b%9c%ec%9e%91-%eb%ac%b8%ec%a0%9c-%ed%95%b4%ea%b2%b0","status":"publish","type":"post","link":"https:\/\/tridenstechnology.com\/ko\/troubleshooting-the-brm-pipeline-start-up\/","title":{"rendered":"BRM \ud30c\uc774\ud504\ub77c\uc778 \uc2dc\uc791 \ubb38\uc81c \ud574\uacb0"},"content":{"rendered":"<p><strong>Issue 1<\/strong><br \/>\nTo see if all the pipelines are up, use this command: \u00bbpss | grep ifw\u00ab. The output should look like this:<br \/>\n$ pss | grep ifw<br \/>\npin 18601 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 24721 1 0 11:53:28 pts\/0 01:00 bin\/ifw -r .\/custom\/conf\/dia_1_P.reg<br \/>\npin 18603 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18613 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18607 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18612 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18605 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18600 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18618 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18616 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18611 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18614 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18486 1 0 10:48:00 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18610 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18608 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 19123 1 0 10:50:47 pts\/0 00:18 bin\/ifw -r .\/custom\/conf\/rt_1_P.reg<br \/>\npin 18490 18486 0 10:48:00 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18609 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18602 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18617 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18615 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 19130 1 0 10:50:59 pts\/0 01:29 bin\/ifw -r .\/custom\/conf\/mbi_1_P.reg<br \/>\npin 18606 18486 0 10:48:03 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 18604 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync<br \/>\npin 21975 1 0 11:23:18 pts\/0 01:01 bin\/ifw -r .\/custom\/conf\/dcn_1_P.reg<br \/>\npin 19126 1 0 10:50:53 pts\/0 00:17 bin\/ifw -r .\/custom\/conf\/rt_1_S.reg<\/p>\n<p><strong> Issue 2<\/strong><br \/>\nIf you can&#8217;t start the pipeline and you get this error message: \u00bbError: Could not start event handler, cannot proceed.\u00bb, then you need to kill the event handler process. See the example that follows:<br \/>\n\/opt\/portal\/pre_dia\/log\/process\/ $ tail -f dia_1_P.out<br \/>\n;<br \/>\nPipeline Server \/ Version 7.3 10095 started at 06.01.2009 16:23:11.<br \/>\nCopyright (c) 1998 &#8211; 2007 Oracle Corporation. All rights reserved.<\/p>\n<p>Too many failed attempts at starting event handler daemon.<br \/>\nError: Could not start event handler, cannot proceed.<\/p>\n<p>Pipeline Server \/ Version 7.3 10095 finished at 06.01.2009 16:23:11.<\/p>\n<p><strong>Resolution<\/strong>:<br \/>\n$ pss | grep dia<br \/>\npin 27727 1 0 15:50:21 pts\/3 00:00 \/opt\/portal\/pre_dia\/bin\/ifw_eventhandler64<br \/>\npin 3055 4463 1 16:24:18 pts\/3 00:00 grep dia<br \/>\n$ kill -9 27727<\/p>\n<p><strong>Issue 3<\/strong><br \/>\nTo rebalance the MBI pipeline, run the following command:<br \/>\ncd \/opt\/portal\/pre_mbi\/bin\/<br \/>\n.\/pin_ctl snmpset rebalanceAaaGw aaa<\/p>\n<p>To rebalance the DIAMETER pipeline, run the following command:<br \/>\ncd \/opt\/portal\/pre_dia\/bin\/<br \/>\n.\/pin_ctl snmpset rebalanceAaaGw aaa<\/p>\n<p><strong>Issue 4<\/strong><br \/>\nIf you get this error message: \u00bbERR_TAM_INIT_FAILED,\u00ab then you need to delete files in the tam directory.<\/p>\n<p>bin\/ifw: An error occurred during creation.<br \/>\nOriginator : ifw.Pipelines.ExceptionPipeline.TransactionManager<br \/>\nDestination :<br \/>\nMessage : ERR_TAM_INIT_FAILED<br \/>\nArguments : ifw.Pipelines.ExceptionPipeline.TransactionManager<br \/>\nState : false<br \/>\nSeverity : CRITICAL<br \/>\nThread : 1<\/p>\n<p><strong>Resolution<\/strong>:<br \/>\ncd \/opt\/portal\/<br \/>\n\/tam<br \/>\nBackup the files to other location<br \/>\nrm TamTrans*.dat<br \/>\nrm ExceptionBinaryLogFile.dat<\/p>\n<p><strong>Issue 5<\/strong><br \/>\nIf you get this error message: \u00bbERR_REG_LOCK_FILE_EXISTS,\u00ab then you need to delete the lock file.<\/p>\n<p>*** Log not initialised.<br \/>\n*** Tried to write message &#8216;[T:1] ERR_REG_LOCK_FILE_EXISTS&#8217;<br \/>\n*** argument (0): .\/custom\/conf\/rt_1_P.reg.lock<\/p>\n<p>bin\/ifw: An error occurred during creation.<br \/>\nOriginator : ifw<br \/>\nDestination :<br \/>\nMessage : ERR_REG_LOCK_FILE_EXISTS<br \/>\nArguments : .\/custom\/conf\/rt_1_P.reg.lock<\/p>\n<p>State : false<br \/>\nSeverity : CRITICAL<br \/>\nThread : 1<\/p>\n<p><strong>Resolution<\/strong>:<br \/>\ncd \/opt\/portal\/<br \/>\n\/custom\/conf<br \/>\nrm rt_1_P.reg.lock<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Issue 1 To see if all the pipelines are up, use this command: \u00bbpss | grep ifw\u00ab. The output should look like this: $ pss | grep ifw pin 18601 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync pin 24721 1 0 11:53:28 pts\/0 01:00 bin\/ifw -r .\/custom\/conf\/dia_1_P.reg pin 18603 18486 0 10:48:02 pts\/0 00:00 \/opt\/portal\/pin\/bin\/dm_ifw_sync pin&hellip;<\/p>","protected":false},"author":1,"featured_media":3163,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[38],"tags":[],"class_list":["post-743","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oracle-billing","category-38","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.5 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Troubleshooting the BRM Pipeline Start Up - Tridens<\/title>\n<meta name=\"description\" content=\"Troubleshooting the BRM Pipeline Start Up. To see if all the pipelines are up, use this command: \u00bbpss | grep ifw\u00ab\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tridenstechnology.com\/ko\/brm-\ud30c\uc774\ud504\ub77c\uc778-\uc2dc\uc791-\ubb38\uc81c-\ud574\uacb0\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Troubleshooting the BRM Pipeline Start Up\" \/>\n<meta property=\"og:description\" content=\"Troubleshooting the BRM Pipeline Start Up. To see if all the pipelines are up, use this command: \u00bbpss | grep ifw\u00ab\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tridenstechnology.com\/ko\/brm-\ud30c\uc774\ud504\ub77c\uc778-\uc2dc\uc791-\ubb38\uc81c-\ud574\uacb0\/\" \/>\n<meta property=\"og:site_name\" content=\"Tridens\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tridenstechnology\" \/>\n<meta property=\"article:published_time\" content=\"2010-04-13T08:07:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-01T15:36:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/08\/oracle-brm-services.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1934\" \/>\n\t<meta property=\"og:image:height\" content=\"1934\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ale\u0161\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@TridensTech\" \/>\n<meta name=\"twitter:site\" content=\"@TridensTech\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ale\u0161\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\ubd84\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"BRM \ud30c\uc774\ud504\ub77c\uc778 \uc2dc\uc791 \ubb38\uc81c \ud574\uacb0 - Tridens","description":"BRM \ud30c\uc774\ud504\ub77c\uc778 \uc2dc\uc791 \ubb38\uc81c \ud574\uacb0. \ubaa8\ub4e0 \ud30c\uc774\ud504\ub77c\uc778\uc774 \uac00\ub3d9 \uc911\uc778\uc9c0 \ud655\uc778\ud558\ub824\uba74 \ub2e4\uc74c \uba85\ub839\uc744 \uc0ac\uc6a9\ud558\uc138\uc694: \"PSS | GRP IFW\"","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tridenstechnology.com\/ko\/brm-\ud30c\uc774\ud504\ub77c\uc778-\uc2dc\uc791-\ubb38\uc81c-\ud574\uacb0\/","og_locale":"ko_KR","og_type":"article","og_title":"Troubleshooting the BRM Pipeline Start Up","og_description":"Troubleshooting the BRM Pipeline Start Up. To see if all the pipelines are up, use this command: \u00bbpss | grep ifw\u00ab","og_url":"https:\/\/tridenstechnology.com\/ko\/brm-\ud30c\uc774\ud504\ub77c\uc778-\uc2dc\uc791-\ubb38\uc81c-\ud574\uacb0\/","og_site_name":"Tridens","article_publisher":"https:\/\/www.facebook.com\/tridenstechnology","article_published_time":"2010-04-13T08:07:09+00:00","article_modified_time":"2021-12-01T15:36:43+00:00","og_image":[{"width":1934,"height":1934,"url":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/08\/oracle-brm-services.png","type":"image\/png"}],"author":"Ale\u0161","twitter_card":"summary_large_image","twitter_creator":"@TridensTech","twitter_site":"@TridensTech","twitter_misc":{"\uae00\uc4f4\uc774":"Ale\u0161","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"3\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#article","isPartOf":{"@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/"},"author":{"name":"Ale\u0161","@id":"https:\/\/tridenstechnology.com\/#\/schema\/person\/ccd247e07a5e0f856ec13af63d611358"},"headline":"Troubleshooting the BRM Pipeline Start Up","datePublished":"2010-04-13T08:07:09+00:00","dateModified":"2021-12-01T15:36:43+00:00","mainEntityOfPage":{"@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/"},"wordCount":556,"commentCount":25,"publisher":{"@id":"https:\/\/tridenstechnology.com\/#organization"},"image":{"@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#primaryimage"},"thumbnailUrl":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/08\/oracle-brm-services.png","articleSection":["Oracle Billing"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/","url":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/","name":"BRM \ud30c\uc774\ud504\ub77c\uc778 \uc2dc\uc791 \ubb38\uc81c \ud574\uacb0 - Tridens","isPartOf":{"@id":"https:\/\/tridenstechnology.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#primaryimage"},"image":{"@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#primaryimage"},"thumbnailUrl":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/08\/oracle-brm-services.png","datePublished":"2010-04-13T08:07:09+00:00","dateModified":"2021-12-01T15:36:43+00:00","description":"BRM \ud30c\uc774\ud504\ub77c\uc778 \uc2dc\uc791 \ubb38\uc81c \ud574\uacb0. \ubaa8\ub4e0 \ud30c\uc774\ud504\ub77c\uc778\uc774 \uac00\ub3d9 \uc911\uc778\uc9c0 \ud655\uc778\ud558\ub824\uba74 \ub2e4\uc74c \uba85\ub839\uc744 \uc0ac\uc6a9\ud558\uc138\uc694: \"PSS | GRP IFW\"","breadcrumb":{"@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#primaryimage","url":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/08\/oracle-brm-services.png","contentUrl":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/08\/oracle-brm-services.png","width":1934,"height":1934,"caption":"Oracle BRM Services"},{"@type":"BreadcrumbList","@id":"https:\/\/tridenstechnology.com\/troubleshooting-the-brm-pipeline-start-up\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tridenstechnology.com\/"},{"@type":"ListItem","position":2,"name":"Troubleshooting the BRM Pipeline Start Up"}]},{"@type":"WebSite","@id":"https:\/\/tridenstechnology.com\/#website","url":"https:\/\/tridenstechnology.com\/","name":"Tridens","description":"\uc218\uc775 \ucc3d\ucd9c, \uccad\uad6c \ubc0f \uc804\uae30\ucc28 \ucda9\uc804","publisher":{"@id":"https:\/\/tridenstechnology.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tridenstechnology.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/tridenstechnology.com\/#organization","name":"Tridens","url":"https:\/\/tridenstechnology.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/tridenstechnology.com\/#\/schema\/logo\/image\/","url":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/02\/tridens_logo_invert.png","contentUrl":"https:\/\/d2xqcz296oofyv.cloudfront.net\/wp-content\/uploads\/2019\/02\/tridens_logo_invert.png","width":600,"height":191,"caption":"Tridens"},"image":{"@id":"https:\/\/tridenstechnology.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tridenstechnology","https:\/\/x.com\/TridensTech","https:\/\/www.instagram.com\/tridenstechnology\/","https:\/\/www.linkedin.com\/company\/tridens","https:\/\/www.youtube.com\/user\/TridensIT"]},{"@type":"Person","@id":"https:\/\/tridenstechnology.com\/#\/schema\/person\/ccd247e07a5e0f856ec13af63d611358","name":"Ale\u0161","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/0df040b8c52446051022ab32cd2ac1dc64d3c7eed18d5bd5ab9f2992b8935fc8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0df040b8c52446051022ab32cd2ac1dc64d3c7eed18d5bd5ab9f2992b8935fc8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0df040b8c52446051022ab32cd2ac1dc64d3c7eed18d5bd5ab9f2992b8935fc8?s=96&d=mm&r=g","caption":"Ale\u0161"},"description":"\uc54c\ub808\uc2a4 \ud504\ub9ac\uc2a4\ud1a0\ube0c\ub2c9\uc740 \uc790\ub3d9\ucc28 \uc0b0\uc5c5\uc744 \uc704\ud55c \uc18c\ud504\ud2b8\uc6e8\uc5b4 \uc194\ub8e8\uc158 \uac1c\ubc1c\uc744 \uc804\ubb38\uc73c\ub85c \ud558\ub294 \uc2ac\ub85c\ubca0\ub2c8\uc544 \ud68c\uc0ac Tridens Technology\uc758 CEO\uc785\ub2c8\ub2e4. \uacfc\uac70\uc5d0 \uc5ec\ub7ec \ub300\uae30\uc5c5\uc5d0\uc11c \uadfc\ubb34\ud55c \uacbd\ub825\uc774 \uc788\ub294 \uadf8\ub294 IT \uc5c5\uacc4\uc5d0\uc11c \uc624\ub79c \uacbd\ub825\uc744 \uc313\uc558\uc2b5\ub2c8\ub2e4. \uae30\uc220\uacfc \ud601\uc2e0\uc5d0 \ub300\ud55c \uc5f4\uc815\uc744 \uac00\uc9c0\uace0 \uc788\uc73c\uba70, \ud604\uc7ac \uc790\ub3d9\ucc28 \uc0b0\uc5c5\uc758 \uc548\uc804\uacfc \ud6a8\uc728\uc131\uc744 \uac1c\uc120\ud560 \uc218 \uc788\ub294 \uc194\ub8e8\uc158\uc744 \uac1c\ubc1c\ud558\ub294 \ub370 \uc8fc\ub825\ud558\uace0 \uc788\uc2b5\ub2c8\ub2e4. \ub9ac\ub354\uc2ed\uacfc \uad00\ub9ac \ubd84\uc57c\uc5d0\uc11c \ud0c4\ud0c4\ud55c \uacbd\ub825\uc744 \uc313\uc558\uc73c\uba70, \ub04a\uc784\uc5c6\uc774 \uc9c4\ud654\ud558\ub294 \uae30\uc220 \ubd84\uc57c\uc5d0\uc11c \ud68c\uc0ac\ub97c \ubc1c\uc804\uc2dc\ud0a4\ub294 \ub370 \uc804\ub150\ud558\uace0 \uc788\uc2b5\ub2c8\ub2e4.","url":"https:\/\/tridenstechnology.com\/ko\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/posts\/743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/comments?post=743"}],"version-history":[{"count":0,"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/posts\/743\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/media\/3163"}],"wp:attachment":[{"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/media?parent=743"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/categories?post=743"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tridenstechnology.com\/ko\/wp-json\/wp\/v2\/tags?post=743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}